 Single-phase Solid State Relays for Heaters
G3PE
Slim Profile Industrial SSR with Heatsink ideal for heater applications.
* Snubber circuit provides excellent short-term surge absorption. * 15A and 25A models have slim 22.5mm width. * Zero cross or "fast turn on" models. * DIN track or panel mounting possible. * LED indicator standard on all single phase models. * UL, CSA and TUV approved. * RoHS compliant.
Refer to Safety Precautions
Ordering Information
List of Models
Number of phases Isolation method Operation indicator Rated input voltage Zero cross function Applicable load * Model 15 A, 100 to 240 VAC G3PE-215B DC12-24 Yes Single-phase Phototriac coupler Yes (yellow) 12 to 24 VDC No 25 A, 100 to 240 VAC G3PE-225B DC12-24 35 A, 100 to 240 VAC G3PE-235B DC12-24 45 A, 100 to 240 VAC G3PE-245B DC12-24 15 A, 100 to 240 VAC G3PE-215BL DC12-24 25 A, 100 to 240 VAC G3PE-225BL DC12-24 35 A, 100 to 240 VAC G3PE-235BL DC12-24 45 A, 100 to 240 VAC G3PE-245BL DC12-24 * The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in the Engineering Data section.
Single-phase Solid State Relays for Heaters
G3PE
427
Specifications
Ratings
Input (at an Ambient Temperature of 25C)
Item Model G3PE-@@@B G3PE-@@@BL Rated voltage 12 to 24 VDC Operating voltage range 9.6 to 30 VDC Rated input current 7 mA max. 15 mA max. Voltage level Must operate voltage 9.6 VDC max. Must release voltage 1.0 VDC max.
Output
Model Item Rated load voltage Load voltage range Applicable load current * Inrush current Permissible I2t (reference value) Applicable load (resistive load) 0.1 to 15 A (at 40C) G3PE-215B(L) G3PE-225B(L) G3PE-235B(L) G3PE-245B(L) 100 to 240 VAC (50/60 Hz) 75 to 264 VAC (50/60 Hz) 0.1 to 25 A (at 40C) 0.5 to 35 A (at 25C) 0.5 to 45 A (at 25C)
150 A 220 A (60 Hz, 1 cycle) (60 Hz, 1 cycle) 121A2s 3 kW (at 200 VAC) 260A2s 5 kW (at 200 VAC)
440 A (60 Hz, 1 cycle) 1,260A2s 7 kW (at 200 VAC) 9 kW (at 200 VAC)
* The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature
Characteristics
Model Item Operate time Release time Output ON voltage drop Leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient storage temperature Ambient operating temperature Ambient operating humidity Weight G3PE-215B G3PE-225B G3PE-235B G3PE-245B G3PE-215BL 1 ms max. G3PE-225BL G3PE-235BL G3PE-245BL 1/2 of load power source cycle + 1 ms max. 1/2 of load power source cycle + 1 ms max. 1.6 V (RMS) max. 10 mA max. (at 200 VAC) 100 M min. (at 500 VDC) 2,500 VAC, 50/60 Hz for 1 min 10 to 55 to10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) (Mounted to DIN track) Destruction: 294 m/s2 (Mounted to DIN track) -30 to 100C (with no icing or condensation) -30 to 80C (with no icing or condensation) 45% to 85% Approx. 240 g Approx. 400 g Approx. 240 g Approx. 400 g
428
Single-phase Solid State Relays for Heaters
G3PE
Engineering Data
Input Voltage vs. Input Impedance and Input Voltage vs. Input Current
G3PE-2@@B
Input current (mA) Input impedance (k) 10 9 8 7 6 5 4 3 2 1 0 0 5 10 15 20 25 30 35 Input voltage (V) Input impedance Input current Ta = 25C
G3PE-2@@BL
Input impedance (k) Input current (mA) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 5 Ta = 25C
Input current
Input impedance
10
15
20
25 30 35 Input voltage (V)
Load Current vs. Ambient Temperature
G3PE-215B(L), G3PE-225B(L)
Load current (A) 30 25 G3PE-@25B(L) 20
G3PE-235B(L), G3PE-245B(L)
Load current (A) 50 45 40 35 30 G3PE-235B(L) G3PE-245B(L)
15 G3PE-@15B(L) 10 7 20 18 17 14 10
0 -30
-20
0
20
40 60 80 100 Ambient temperature (C)
0 -30
-20
0
20 25 40 60 80 100 Ambient temperature (C)
Inrush Current Resistivity: Non-repetitive
Make sure the inrush current stays below the dashed line curve if it occurs repetitively.
G3PE-215B(L)
Inrush current (A. Peak) 250
G3PE-225B(L)
Inrush current (A. Peak) 250
G3PE-235B(L), G3PE-245B(L)
Inrush current (A. Peak) 500
200
200
400
150
150
300
100
100
200
50
50
100
0 10
30 50 100
300 500 1,000 3,000 5,000 Energized time (ms)
0 10
30 50 100
300 500 1,000 3,000 5,000 Energized time (ms)
0 10
30 50 100
300 500 1,000 3,000 5,000 Energized time (ms)
Single-phase Solid State Relays for Heaters
G3PE
429
Close Mounting (3 or 8 SSRs)
G3PE-215B(L)
Load current (A) 20
G3PE-225B(L)
Load current (A) 30 25 3 Relays 20 19 15 8 Relays
G3PE-235B(L)
Load current (A) 40 3 Relays 30 28 26 20 8 Relays
G3PE-245B(L)
Load current (A) 50
3 Relays 15 13 12 10 8 Relays
40 3 Relays 31 30 29 8 Relays 20
5.7 5
10 8 7 5 0 -40
11 10
11 10 0 -40
0 -40
-20
0
20 40 60 80 100 Ambient temperature (C)
-20
0
20 40 60 80 100 Ambient temperature (C)
0 -40
-20
0
20 25 40 60 80 100 Ambient temperature (C)
-20
0
20 25
40
60
80 100
Ambient temperature (C)
Close Mounting Example
DIN Track
Approvals
UL Recognized, CSA Certified and EN60947-4-3 (TUV) approved
430
Single-phase Solid State Relays for Heaters
G3PE
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Solid State Relays
G3PE-215B(L) G3PE-225B(L)
130.2 Two, M4 Two, 4.6 dia.
100 max. 68 24 900.2 84
Two, M3.5 4.2 6.3 Note: Without terminal cover. Mounting Holes 130.3 4.6 x 5.6 elliptical hole 4.5 22.5 max.
Note: With terminal cover.
Terminal Arrangement/Internal Circuit Diagram
G3PE-5@@B
1
G3PE-2@@B
(+) A1
1
(+) A1
Output side
Output side
Input side
(100) 900.3 (85) (90)
A2
A2
Three, 4.5 dia. or M4
2
)-(
2
)-(
G3PE-235B(L) G3PE-245B(L)
250.2 Two, M5
4.6 dia.
100 max. 68 24 900.2 84 Two, M3.5
6
13.5
4.6 x 5.6 elliptical hole
44.5 max.
Note: Without terminal cover. Mounting Holes 250.3
Note: With terminal cover.
Terminal Arrangement/Internal Circuit Diagram
G3PE-5@@B
1
G3PE-2@@B
(+) A1
Input side
(+) A1
Trigger circuit
Trigger circuit
Input circuit
Output side
Output side
Input circuit
1
Input side
(100) 900.3 (85) (90)
A2
A2
Three, 4.5 dia. or M4
2
)-(
2
)-(
Single-phase Solid State Relays for Heaters
G3PE
Input side
Trigger circuit
Trigger circuit
Input circuit
Input circuit
431
Safety Precautions
Refer to Safety Precautions for All Solid State Relays. Installation and Handling
!CAUTION
Minor electrical shock may occasionally occur. Do not touch the G3PE terminal section (i.e., currentcarrying parts) while the power is being supplied. Also, always attach the cover terminal. The G3PE may rupture if short-circuit current flows. As protection against accidents due to shortcircuiting, be sure to install protective devices, such as fuses and no-fuse breakers, on the power supply side. Minor electrical shock may occasionally occur. Do not touch the main circuit terminals on the SSR immediately after the power supply has been turned OFF. Shock may result due to the electrical charge stored in the built-in snubber circuit. Minor burns may occasionally occur. Do not touch the SSR or the heatsink while the power is being supplied or immediately after the power supply has been turned OFF. The SSR and heatsink become extremely hot. * Do not block the movement of the air surrounding the G3PE or heat sink. Abnormal heating of the G3PE may result in shorting failures of the output elements or burn damage. * Do not use the G3PE if the heat radiation fins have been bent by being dropped. Doing so may result in malfunction due to a reduction in the heat radiation performance. * Do not handle the G3PE with oily or dusty (especially iron dust) hands. Doing so may result in malfunction. * Attach a heat sink or radiator when using an SSR. Not doing so may result in malfunction due to a reduction in the heat radiation performance.
Installation and Mounting
* Mount the G3PE in the specified direction. Otherwise excessive heat generated by the G3PE may cause short-circuit failures of the output elements or burn damage. * Make sure that there is no excess ambient temperature rise due to the heat generation of the G3PE. If the G3PE is mounted inside a panel, install a fan so that the interior of the panel is fully ventilated. * Make sure the DIN track is securely mounted. Otherwise, the G3PE may fall. * When mounting the heat sink, do not allow any foreign matter between the heat sink and the mounting surface. Foreign matter may cause malfunction due to a reduction in the heat radiation performance. * If the G3PE is mounted directly in a control panel, use aluminum, steel plating, or similar material with a low heat resistance as a substitute for a heat sink. Using the G3PE mounted in wood or other material with a high heat resistance may result in fire or burning due to heat generated by the G3PE.
Precautions for Safe Use
OMRON constantly strives to improve quality and reliability. SSRs, however, use semiconductors, and semiconductors may commonly malfunction or fail. In particular, it may not be possible to ensure safety if the SSRs are used outside the rated ranges. Therefore, always use the SSRs within the ratings. When using an SSR, always design the system to ensure safety and prevent human accidents, fires, and social harm in the event of SSR failure. System design must include measures such as system redundancy, measures to prevent fires from spreading, and designs to prevent malfunction.
Installation and Wiring
* Use wires that are suited to the load current. Otherwise, excessive heat generated by the wires may cause burning. * Do not use wires with a damaged outer covering. Otherwise, it may result in electric shock or ground leakage. * Do not wire any wiring in the same duct or conduit as power or high-tension lines. Otherwise, inductive noise may damage the G3PE or cause it to malfunction. * When tightening terminal screws, prevent any non-conducting material from becoming caught between the screws and the tightening surface. Otherwise, excessive heat generated by the terminal may cause burning. * Do not use the G3PE with loose terminal screws. Otherwise, excessive heat generated by the wire may cause burning. * For the G3PE models with a carry current of 35 A or larger, use M5 crimp terminals that are an appropriate size for the diameter of the wire. * Always turn OFF the power supply before performing wiring. Not doing so may cause electrical shock.
Transport
Do not transport the G3PE under the following conditions. Doing so may result in damage, malfunction, or deterioration of performance characteristics. * Conditions in which the G3PE may be subject to water. * Conditions in which the G3PE may be subject to high temperature or high humidity. * Conditions in which the G3PE is not packaged.
Operating and Storage Environments
Do not use or store the G3PE in the following locations. Doing so may result in damage, malfunction, or deterioration of performance characteristics. * * * * * * * * * Locations subject to rainwater or water splashes. Locations subject to exposure to water, oil, or chemicals. Locations subject to high temperature or high humidity. Do not store in locations subject to ambient storage temperatures outside the range -30 to 100C. Do not use in locations subject to relative humidity outside the range 45% to 85%. Locations subject to corrosive gases. Locations subject to dust (especially iron dust) or salts. Locations subject to direct sunlight. Locations subject to shock or vibration.
Installation and Usage
* Select a load within the rated values. Not doing so may result in malfunction, failure, or burning. * Select a power supply within the rated frequencies. Not doing so may result in malfunction, failure, or burning. * The G3PE provides a circuit to prevent photocoupler damage by forcibly arcing the output element for surge voltages applied to the load. The G3PE therefore cannot be used for motor loads. Doing so may result in load motor malfunction.
432
Single-phase Solid State Relays for Heaters
G3PE
Precautions for Correct Use
The SSR in operation may cause an unexpected accident. Therefore it is necessary to test the SSR under the variety of conditions that are possible. As for the characteristics of the SSR, it is necessary to consider differences in characteristics between individual SSRs. The ratings in this catalog are tested values in a temperature range between 15C and 30C, a relative humidity range between 25% and 85%, and an atmospheric pressure range between 86 and 106 kPa. It will be necessary to provide the above conditions as well as the load conditions if the user wants to confirm the ratings of specific SSRs.
Wiring
* When using crimp terminals, refer to the terminal clearances shown below.
Output Terminal Section for Three-phase Models
7 mm 13 mm
12 mm
M4 (15 A, 25 A) M5 (35 A, 45 A)
Causes of Failure
* Do not drop the G3PE or subject it to abnormal vibration or shock during transportation or mounting. Doing so may result in deterioration of performance, malfunction, or failure. * Tighten each terminal to the torque specified below. Improper tightening may result in abnormal heat generation at the terminal, which may cause burning. Terminals Input terminals Output terminals Screw terminal diameter M3.5 M4 M5 Tightening torque 0.59 to 1.18 N*m 0.98 to 1.47 N*m 1.57 to 2.45 N*m
Output Terminal Section for Single-phase Models
15-A and 25-A Models
10 mm
35-A and 45-A Models
13 mm
12.4 mm
12.9 mm
M4 (15 A, 25 A)
M5 (35 A, 45 A)
Input Terminal Section
7.0 mm
10 mm
* Do not supply overvoltage to the input circuits or output circuits. Doing so may result in failure or burning. * Do not use or store the G3PE in the following conditions. Doing so may result in deterioration of performance. * Locations subject to static electricity or noise * Locations subject to strong electric or magnetic fields * Locations subject to radioactivity
M3.5
Mounting
* The G3PE is heavy. Firmly mount the DIN Track and secure both ends with End Plates for DIN Track mounting models. When mounting the G3PE directly to a panel, firmly secure it to the panel. Screw diameter: M4 Tightening torque: 0.98 to 1.47 N*m
Mounted on a vertical surface Mounted on a horizontal surface
* Make sure that all lead wires are thick enough for the current. * For three-element and two-element models, the output terminal will be charged even when the Relay is OFF. Touching the terminal may result in electric shock. To isolate the Relay from the power supply, install an appropriate circuit breaker between the power supply and the Relay. Always turn OFF the power supply before wiring the Unit. * Terminal L2 and terminal T2 of a 2-element model are internally connected to each other. Connect terminal L2 to the ground terminal of the power supply. If terminal L2 is connected to a terminal other than the ground terminal, cover all the charged terminals, such as heater terminals, to prevent electric shock and ground faults.
Fuses
* Use a quick-burning fuse on the output terminals to prevent accidents due to short-circuiting. Use a fuse with equal or greater performance than those given in the following table.
Vertical Direction Panel Panel
Recommended Fuse Capacity
Rated G3PE output current 15 A 25 A 35 A 45 A Applicable SSR G3PE@15B Series G3PE@25B Series G3PE@35B Series G3PE@45B Series Fuse (IEC 60269-4) 32 A 63 A
Note: Make sure that the load current is 50% of the rated load current when the G3PE is mounted horizontally. For details on close mounting, refer to the related information under performance characteristics. Mount the G3PE in a direction so that the markings read naturally.
Single-phase Solid State Relays for Heaters
G3PE
433
EMC Connection
Make EMC connections according to the following figure. * Connect a capacitor to the load power supply. * The input cable must be no longer than 3 m.
Load
Input G3PE Output
Mounting to Control Panel
The G3PE is heavy. Firmly mount the DIN track and secure both ends with End Plates for DIN-track-mounting models. When mounting the G3PE directly to a panel, firmly secure it to the panel. If the panel is airtight, heat from the SSR will build up inside, which may reduce the current carry ability of the SSR or adversely affect other electrical devices. Be sure to install ventilation holes on the top and bottom of the panel.
SSR Mounting Pitch (Panel Mounting)
* Single-phase Model
3 m max. Recommended Capacitor (Film Capacitor) G3PE-2@@B Series: 1 F, 250 VAC G3PE-5@@B Series: 0.5 F, 500 VAC
Duct or other object blocking airflow Between duct and G3PE SSR 10 mm min. 60 mm min.
EMI
This is a Class A product (for industrial environments). In a domestic environment, the G3PE may cause radio interference, in which case the user may be required to take appropriate measures.
Mounting direction Vertical Direction Between duct and G3PE 30 mm min. 80 mm min.
Noise and Surge Effects
If noise or an electrical surge occurs that exceeds the malfunction withstand limit for the G3PE output circuit, the output will turn ON for a maximum of one half cycle to absorb the noise or surge. Confirm that turning the output ON for a half cycle will not cause a problem for the device or system in which the G3PE is being used prior to actual use. The G3PE malfunction withstand limit is shown below. * Malfunction withstand limit (reference value): 500 V Note: This value was measured under the following conditions. Noise duration: 100 ns and 1 s Repetition period: 100 Hz Noise application time: 3 min
Host and slave
Mounting Models with Externally Attached Heat Sinks
* Before attaching an external Heat Sink or Radiator to the Unit, always apply silicone grease, such as Toshiba Silicone's YG6260 or Sinetsu Silicone's G746, to the mounting surface to enable proper heat radiation. * Tighten the screws to the following torque to secure the Unit and external Heat Sink or Radiator to enable proper heat dissipation. Tightening torque: 2.0 N*m
434
Single-phase Solid State Relays for Heaters
G3PE
Relationship between the G3PE and Ducts or Other Objects Blocking Airflow
Incorrect Example
Duct or other object blocking airflow
Countermeasure 1
50 mm max. (No more than 1/2 the SSR depth is recommended.) Duct
Countermeasure 2
Duct
Airflow
Mounting surface
Mounting surface
Vertical Direction
Mounting surface
Base
SSR
SSR
SSR
Duct If the depth direction of the G3PE is obstructed by ducts, the heat radiation will be adversely affected.
Duct Use ducts that have a shallow depth, to provide a sufficient ventilation area.
Duct If the ducts cannot be made lower, place the G3PE on a metal base so that it is not surrounded by the ducts.
Ventilation Outside the Control Panel
Duct or other object blocking airflow Be aware of airflow
SSR SSR
Ventilation outlet (Axial Fan)
SSR
Air inlet
Note: 1. If the air inlet or air outlet has a filter, clean the filter regularly to prevent it from clogging to ensure an efficient flow of air. 2. Do not locate any objects around the air inlet or air outlet, otherwise the objects may obstruct the proper ventilation of the control panel. 3. A heat exchanger, if used, should be located in front of the G3PE to ensure the efficiency of the heat exchanger.
G3PE Ambient Temperature
15A and 25A models have ambient temperature of 40C, while 35A and 45A models have 25C ambient Temperature. The G3PE uses a semiconductor to switch the load. This causes the temperature inside the control panel to increase due to heating resulting from the flow of electrical current through the load. The G3PE reliability can be increased by adding a ventilation fan to the control panel to dispel this heat, thus lowering the ambient temperature of the G3PE. (Arrhenius's law suggests that life expectancy is doubled by each 10C reduction in ambient temperature.) SSR rated current (A) Required number of fans per SSR 15 A 0.23 25 A 0.39 35 A 0.54 45 A 0.70
Example: For 10 G3PE SSRs with load currents of 15 A, 0.23 x 10 = 2.3 Thus, 3 fans would be required. Note: 1. Size of fans: 92 mm x 92 mm, Air volume: 0.7 m3/min, Ambient temperature of control panel: 30C 2. If there are other instruments that generate heat in the control panel in addition to SSRs, more ventilation will be required. 3. Ambient temperature: The temperature that will allow the SSR to cool by convection or other means.
Single-phase Solid State Relays for Heaters
G3PE
435
MEMO
436
Single-phase Solid State Relays for Heaters
G3PE
Omron Electronic Components, LLC
Terms and Conditions of Sales I. GENERAL 1. Definitions: The words used herein are defined as follows. (a) Terms: These terms and conditions (b) Seller: Omron Electronic Components LLC and its subsidiaries (c) Buyer: The buyer of Products, including any end user in section III through VI (d) Products: Products and/or services of Seller (e) Including: Including without limitation 2. Offer; Acceptance: These Terms are deemed part of all quotations, acknowledgments, invoices, purchase orders and other documents, whether electronic or in writing, relating to the sale of Products by Seller. Seller hereby objects to any Terms proposed in Buyer's purchase order or other documents which are inconsistent with, or in addition to, these Terms. 3. Distributor: Any distributor shall inform its customer of the contents after and including section III of these Terms. II. SALES 1. Prices; Payment: All prices stated are current, subject to change without notice by Seller. Buyer agrees to pay the price in effect at the time the purchase order is accepted by Seller. Payments for Products received are due net 30 days unless otherwise stated in the invoice. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. 2. Discounts: Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (a) the invoice is paid according to Seller's payment terms and (b) Buyer has no past due amounts owing to Seller. 3. Interest: Seller, at its option, may charge Buyer 1.5% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 4. Orders: Seller will accept no order less than 200 U.S. dollars net billing. 5. Currencies: If the prices quoted herein are in a currency other than U.S. dollars, Buyer shall make remittance to Seller at the then current exchange rate most favorable to Seller; provided that if remittance is not made when due, Buyer will convert the amount to U.S. dollars at the then current exchange rate most favorable to Seller available during the period between the due date and the date remittance is actually made. 6. Governmental Approvals: Buyer shall be responsible for all costs involved in obtaining any government approvals regarding the importation or sale of the Products. 7. Taxes: All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Seller or required to be collected directly or indirectly by Seller for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Seller. 8. Financial: If the financial position of Buyer at any time becomes unsatisfactory to Seller, Seller reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Seller may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc: Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Seller fully against all costs or expenses arising in connection therewith. 10. Force Majeure: Seller shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery: Unless otherwise expressly agreed in writing by Seller: (a) All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Seller), at which point title to and all risk of loss of the Products shall pass from Seller to Buyer, provided that Seller shall retain a security interest in the Products until the full purchase price is paid by Buyer; (b) Delivery and shipping dates are estimates only; and (c) Seller will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims: Any claim by Buyer against Seller for shortage or damage to the Products occurring before delivery to the carrier or any claim related to pricing or other charges must be presented in detail in writing to Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability: IT IS THE BUYER'S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER'S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E) SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT. Buyer acknowledges that it alone has determined that the Products will meet their requirements of the intended use in all cases. Buyer must know and observe all prohibitions of use applicable to the Product/s. 2. Use with Attention: The followings are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible use of any Product, nor to imply that any use listed may be suitable for any Product: (a) Outdoor use, use involving potential chemical contamination or electrical interference.
(b) Use in consumer Products or any use in significant quantities. (c) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (d) Systems, machines, and equipment that could present a risk to life or property. 3. Prohibited Use: NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 4. Motorized Vehicle Application: USE OF ANY PRODUCT/S FOR A MOTORIZED VEHICLE APPLICATION MUST BE EXPRESSLY STATED IN THE SPECIFICATION BY SELLER. 5. Programmable Products: Seller shall not be responsible for the Buyer's programming of a programmable Product. IV. WARRANTY AND LIMITATION 1. Warranty: Seller's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Seller (or such other period expressed in writing by Seller). SELLER MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT ALL OTHER WARRANTIES, NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. 2. Buyer Remedy: Seller's sole obligation hereunder shall be to replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product or, at Seller's election, to repay or credit Buyer an amount equal to the purchase price of the Product; provided that there shall be no liability for Seller or its affiliates unless Seller's analysis confirms that the Products were correctly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Seller before shipment. 3. Limitation on Liability: SELLER AND ITS AFFILIATES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. FURTHER, IN NO EVENT SHALL LIABILITY OF SELLER OR ITS AFFILITATES EXCEED THE INDIVIDUAL PRICE OF THE PRODUCT ON WHICH LIABILITY IS ASSERTED. 4. Indemnities: Buyer shall indemnify and hold harmless Seller, its affiliates and its employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. V. INFORMATION; ETC. 1. Intellectual Property: The intellectual property embodied in the Products is the exclusive property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way without the written permission of Seller. Buyer (at its own expense) shall indemnify and hold harmless Seller and defend or settle any action brought against Seller to the extent that it is based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. 2. Property; Confidentiality: Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Seller. All information and materials supplied by Seller to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. 3. Performance Data: Performance data is provided as a guide in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must correlate it to actual application requirements. 4. Change In Specifications: Product specifications and descriptions may be changed at any time based on improvements or other reasons. It is Seller's practice to change part numbers when published ratings or features are changed, or when significant engineering changes are made. However, some specifications of the Product may be changed without any notice. 5. Errors And Omissions: The information on Seller's website or in other documentation has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 6. Export Controls: Buyer shall comply with all applicable laws, regulations and licenses regarding (a) export of the Products or information provided by Seller; (b) sale of Products to forbidden or other proscribed persons or organizations; (c) disclosure to noncitizens of regulated technology or information. VI. MISCELLANEOUS 1. Waiver: No failure or delay by Seller in exercising any right and no course of dealing between Buyer and Seller shall operate as a waiver of rights by Seller. 2. Assignment: Buyer may not assign its rights hereunder without Seller's written consent. 3. Law: These Terms are governed by Illinois law (without regard to conflict of laws). Federal and state courts in Cook County, Illinois have exclusive jurisdiction for any dispute hereunder. 4. Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision.
Single-phase Solid State Relays for Heaters
G3PE
Certain Precautions on Specifications and Use
1. Suitability for Use. Seller shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in Buyer's application or use of the Product. At Buyer's request, Seller will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases but the following is a nonexhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iii) Use in consumer products or any use in significant quantities. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 2. Programmable Products. Seller shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 3. Performance Data. Performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to Seller's Warranty and Limitations of Liability. 4. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Seller representative at any time to confirm actual specifications of purchased Product. 5. Errors and Omissions. The information in this publication has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors, or omissions. 6. RoHS Compliance. Where indicated, our products currently comply, to the best of our knowledge as of the date of this publication, with the requirements of the European Union's Directive on the Restriction of certain Hazardous Substances ("RoHS"), although the requirements of RoHS do not take effect until July 2006. These requirements may be subject to change. Please consult our website for current information.
Complete "Terms and Conditions of Sale" for product purchase and use are on Omron's website at http://www.components.omron.com - under the "About Us" tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ELECTRONIC COMPONENTS LLC
55 E. Commerce Drive, Suite B Schaumburg, IL 60173
OMRON ON-LINE
Global - http://www.omron.com USA - http://www.components.omron.com
847-882-2288
Cat. No. X301-E-1A 02/10 Specifications subject to change without notice Printed in USA
Single-phase Solid State Relays for Heaters
G3PE


▲Up To Search▲   

 
Price & Availability of G3PE-215BL

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X